light tester system
test volt, WR,FR
(8)Standards | ||||||||
Watt | Wr | fr | ||||||
11W | 10.8±1.3 W | 56.1±4 KHz | ||||||
14W | 13.5±1.4 W | 56.9±4 KHz | ||||||
19W | 18.9±2.2 W | 53.5±4 KHz | ||||||
22W | 17.6±2.0 W | 46.6±4 KHz | ||||||
Inspection Method: | ||||||||
1.Connect Check wire(CH3,CH4/CH5,CH6) to pin (P3,P4/P5,P6) connected. [Load Resistor: 600 ohm] | ||||||||
( 300ohm resistor*2 [300Ω30W Cement resistor] series connection. ) | ||||||||
2.Connect Check wire(CH1,CH2)with power source of AC220V/50Hz to Lands or Wire (F1,P2). | ||||||||
3.Measure DATA (Wr/fr) after 2 seconds from turn on. | ||||||||
4.Turn off AC220V/50Hz, then Switch off the Load Resistor. | ||||||||
<<Caution>> | ||||||||
(1) You should not to pull strongly when Wr/fr is measured. | ||||||||
(2)Since a measuring method is different compared with other types, Pls Be careful. |